B.4.8 project data, B.4.8, Project data – Festo Контроллеры двигателя SFC-LAC User Manual
Page 299: B−79, B.4.8 project data general project data
Advertising
B. Parametrizing via field bus
B−79
Festo GDCP−SFC−LACI−DN−EN en 0812NH
B.4.8
Project data
General project data
Project Zero Point
PNU
500
ć
int32
rw
Description
Offset of axis zero point to project zero point.
Reference point for target positions with absolute positioning
(compare PNU 401 and 404).
CI
21F4h
00h
int32
rw
DeviceNet
C: 105
Aā: 1
I: 1
int32
rw
Software End Positions
PNU
501
1 ... 2
int32
rw
Description
Software end positions in increments
Plausibility rule: Min. limit
Ţ Max. limit
Factory settings: see section 5.2.6
Lower Limit 501
1
Lower software end position: Offset from axis zero point
Upper Limit 501
2
Upper software end position: Offset from axis zero point
CI
607Bh
01h ... 02h
int32
rw
DeviceNet
C: 105
Aā: 2 ... 3
I: 1
int32
rw
Advertising