Festo Контроллеры двигателя SFC-LAC User Manual

Page 176

Advertising
background image

5. Commissioning

5−72

Festo GDCP−SFC−LACI−DN−EN en 0812NH

5.6.7

Direct mode: Continuous setpoint specification (Continuous Mode)

With continuous setpoint specification (Following mode) the
higher level controller continuously specifies position values
at fixed time intervals (typically 4 ... 10Ăms). Since this time
interval is usually longer than a position controller cycle
(350ĂĢs , the controller independently interpolates the values
between the specified position values. At every specified
interval, the CDIR.B4 CONTT (Toggle Bit") must be toggled to
ensure that any new interval is recognised.

CONTT

0

1

1

2

1

Specified interval (PNU 570)

2

Position controller cycle (350ĂĢs)

Fig. 5/7:

Continuous setpoint specification
(FHPPĂContinuous Mode)

Advertising