B. Parametrizing via field bus
B−47
Festo GDCP−SFC−LACI−DN−EN en 0812NH
Data Memory Control
PNU
127
1 ... 2
uint8
w
Description
Commands for EEPROM
Subindex 03: See 20F1h
Delete EEPROM 127
1
Fixed: 16 (0x10): Delete data in EEPROM.
Once the object has been written, and after power off/on, the data in the
EEPROM are reset to the factory settings.
Save Data 127
2
The data in EEPROM will be overwritten with the current user−specific settings.
Fix 1 (0x01): Save data
CI
20F1h
01h ... 02h
uint8
w
DeviceNet
C: 100
Aā: 20 ... 21
I: 1
uint8
w
Note
All user−specific settings will be lost on deletion (except for
cycle number). The status after deletion corresponds to
the standard factory setting.
·
Always carry out a first commissioning after deleting the
EEPROM.
·
When the EEPROM is deleted, the field bus address is
also reset.