Festo Контроллеры двигателя SFC-LAC User Manual
Page 165
5. Commissioning
5−61
Festo GDCP−SFC−LACI−DN−EN en 0812NH
3. Teaching takes place via the handshake of the bits in the
FHPP control and status bytes CPOS/SPOS:
1
Ready for teaching
2
Value transferred
1
0
Acknowledgement
SPOS.B3
Teach value
CPOS.B5
1
2
1
0
Fig. 5/2:
Handshake when teaching
The drive must not stand still for teaching. However, a speed
of 1 m/s means that the actual position changes by 1 mm
every millisecond. With the usual cycle times of the PLC +
fieldĂbus + motor controller there will be inaccuracies of
several millimetres even at a speed of only 100 mm/s.
Overview of parameters involved (see sections B.4.7 and B.4.8)
Parameters involved
Description
FCT
PNU
CI
Teach target
ć
1)
520
21FCh
Record number
ć
1)
400
2033h
Start (FHPP)
CPOS.B5 = falling edge: Teach value
Feedback (FHPP)
SPOS.B3 = 1: Value transferred
Prerequisites
Device control by PLC/field bus
Controller must be in status Operation enabled"
1)
Teaching is made possible in the Festo Configuration Tool by means of special functions.
Tab. 5/15:
Parameters involved in teaching