5. Commissioning

5−61

Festo GDCP−SFC−LACI−DN−EN en 0812NH

3. Teaching takes place via the handshake of the bits in the

FHPP control and status bytes CPOS/SPOS:

1

Ready for teaching

2

Value transferred

1

0

Acknowledgement
SPOS.B3

Teach value
CPOS.B5

1

2

1

0

Fig. 5/2:

Handshake when teaching

The drive must not stand still for teaching. However, a speed
of 1 m/s means that the actual position changes by 1 mm
every millisecond. With the usual cycle times of the PLC +
fieldĂbus + motor controller there will be inaccuracies of
several millimetres even at a speed of only 100 mm/s.

Overview of parameters involved (see sections B.4.7 and B.4.8)

Parameters involved

Description

FCT

PNU

CI

Teach target

ć

1)

520

21FCh

Record number

ć

1)

400

2033h

Start (FHPP)

CPOS.B5 = falling edge: Teach value

Feedback (FHPP)

SPOS.B3 = 1: Value transferred

Prerequisites

Device control by PLC/field bus
Controller must be in status Operation enabled"

1)

Teaching is made possible in the Festo Configuration Tool by means of special functions.

Tab. 5/15:

Parameters involved in teaching