[Settings] [Homing paramet.]

Setting the homing method and the speed during reference
travel.

·

Observe the instructions in section 5.2.2.

[Homing
paramet.]

Parameter

Description

[Homing method]

switch negative

Homing to the integrated
reference switch at the
retracted end position with
index search

block negative

Homing to a negative fixed
stop

block positive

Homing to positive fixed
stop

Note: Further homing run methods can only be
configured via FCT.

[Velocity v_rp]

v_rp

Speed for searching for the
reference point

[Velocity v_zp]

v_zp

Speed for moving to the
axis zero point

[SAVE...]

Save parameters in EEPROM

Note
A new homing run must always be carried out after
modifying the homing run method.

The maximum speed for homing is subject to built−in limits.