B. Parametrizing via field bus

B−97

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Drive Data

PNU

1026

Various

uint32

r(w)

Description

General data of the SFC−LACI

Output Stage

Temp

1026

1 (CI: 01h)

Aā: 49

r

Temp

Temperature of the SFC−LACI. Range: −20 ... +120 °C

Output Stage

Max Temp

1026

2 (CI: 02h)

Aā: 50

r

Max Temp

Highest temperature measured to date for the SFC−LACI, in °C.
Stored in EEPROM

Max Current

1026

4 (CI: 04h)

Aā: 52

rw

Current limiting. Identical to PNU 1034 / 6073h and 6510/41h

Device Control 1026

6 (CI: 06h)

Aā: 54

rw

Identical to PNU 125 / 207Dh
Bit 0 = 0: Control interface OFF, control via HMI or FCT ON
Bit 0 = 1: Control interface ON
To enable FCT control after the control interface has been switched off,
set ENABLE OPERATION in the control word as well (objectĂ6040h)

Controller Serial

Number

1026

7 (CI: 07h)

Aā: 55

r

Number

Serial number of the controller

CI

6510h

Various

uint32

r(w)

Further subindices of 6510h: see section C.3

DeviceNet

C: 107

Aā: 49 ... 55

I: 1

uint32

r(w)

I

2

t Value

PNU

1027

ć

uint32

r

Description

Current I

2

t value. See PNU 1025/4

CI

6410h

04h

uint32

r

DeviceNet

C: 107

Aā: 41

I: 1

uint32

r