A. Technical appendix

A−6

Festo GDCP−SFC−LACI−DN−EN en 0812NH

A.3

Converting the units of measurement

The CI interface works with increments [Inc, Inc/s, Inc/s

2

,

Inc/s

3

].

DNCE−...−LAS

The distance between two index lines (= north or south pole
of the magnetic displacement encoder) is

5 mm. The resolĆ

ution of the measurement system is 11 bits, which is the
same as 2048

d

(800

h

) increments. The increments are calcuĆ

lated by means of interpolation. This results in the following
conversions (all figures are decimal):

[Inc]

> [mm]

mm

+ xĄInc

2048ĄInc

5Ąmm

[mm]

> [Inc]

Inc

+ xĄmm

5Ąmm

2048ĄInc

DFME−...−LAS

The distance between two index lines (= north or south pole
of the magnetic displacement encoder) is

2 mm.

The resolution of the measurement system is 11 bits, which is
the same as 2048

d

(800

h

) increments. The increments are

calculated by means of interpolation. This results in the
following conversions (all figures are decimal):

[Inc]

> [mm]

mm

+ xĄInc

2048ĄInc

2Ąmm

[mm]

> [Inc]

Inc

+ xĄmm

2Ąmm

2048ĄInc