Page 313

Advertising
background image

B. Parametrizing via field bus

B−93

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Homing Velocities

PNU

1012

1 ... 2

int32

rw

Description

Speeds during homing

Search REF 1012

1

Speed when searching for the reference point REF in [Inc/s]

Search AZ 1012

2

Speed of travel to the axis zero point AZ in [Inc/s]

CI

6099h

01h ... 02h

int32

rw

DeviceNet

C: 107

Aā: 22 ... 23

I: 1

int32

rw

Homing Required

PNU

1014

ć

uint8

r

Description

Defines whether or not homing must be carried out after switching on in order
to carry out positioning tasks.
Fixed = 0: Homing run must be carried out

CI

23F6h

00h

uint8

r

DeviceNet

C: 107

Aā: 25

I: 1

uint8

r

Homing Max Torque/Force

PNU

1015

ć

uint8

rw

Description

Maximum force during homing in [%]
Value range: 10 ... 100

CI

23F7h

00h

uint8

rw

DeviceNet

C: 107

Aā: 26

I: 1

uint8

rw