background image

B. Parametrizing via field bus

B−3

Festo GDCP−SFC−LACI−DN−EN en 0812NH

B.1

Parameterising via Explicit Messaging

B.1.1

DeviceNet Classes

Class

CLASS

1)

Description

Device Data

100 (0x64)

Device identification and device−specific settings, version
numbers, identifier words, control panel polling, etc.

Diagnosis Buffer

101 (0x65)

Memory for diagnostic events:
Fault numbers, fault time, incoming/outgoing event

Diagnosis Buffer
Administration
(diagnosis buffer
management)

102 (0x66)

Administration of the diagnostic memory

Process Data

103 (0x67)

Current nominal and actual values, local I/Os, status data,
record numbers, etc.

Record Sets
(record list)

104 (0x68)

A record contains all the nominal value parameters required
for a positioning procedure

Project Data

105 (0x69)

Basic project settings. Maximum speed and acceleration,
offset project zero point etc.

–> Parameters are the basis

for the record list.

Factor Group

106 (0x6A)

Reserved

Axis Data

107 (0x6B)

All axis−specific parameters for electric drives.
Gear factor, feed constant, reference parameter, etc.

System Diagnosis

108 (0x6C)

Reading or deleting the current device malfunction

Fieldbus Diagnosis

109 (0x6D)

Current connection status and field bus settings,
e.Ăg. baud rate, I/O data length

1)

Class number as per DeviceNet specification

Tab. B/1:

DeviceNet Classes