5. Commissioning

5−83

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Parameter / Description

CI

FCT

PNU

Out2: Setting condition rising/falling
Value = 0: The output is set if the reference value accrued from lower

values has been reached in accordance with 2422/04h.

Value = 1: The output is set if the reference value accrued from higher

values has been reached in accordance with 2422/04h.

1255

x

2422/06h

Out2: Resetting condition rising/falling
Value = 0: The output is reset if the reference value accrued from lower

values has been reached in accordance with 2422/05h.

Value = 1: The output is reset if the reference value accrued from higher

values has been reached in accordance with 2422/05h.

1256

x

2422/07h

Out2: Delay
Delay time in [ms] after a resetting condition has occurred. The output is
not reset until the delay time has expired (= switch−off delay).

1257

x

2422/08h

Out2: Inverted
0 = not inverted
1 = inverted
This setting is not taken into account when the output is used for a
brake/clamping unit (see 2422/01h).

1258

x

2422/09h

Out2: PWM value
Duty cycle during a period of time. See Fig. 5/9.
Values: 1 ... 100 %
Value = 0 deactivates the pulse−width modulation

1259

x

2422/0Ah

Tab. 5/21:

Parameters for the local digital outputs