4. Control panel (only type SFC−LACI−...−H2)

4−10

Festo GDCP−SFC−LACI−DN−EN en 0812NH

[Diagnostic] [...]

Description

[DeviceNet Diag]

Bus diagnosis

Ĉ No Power /

BUSĂOff

No bus supply connected or the field bus was not
correctly parameterised. No connection to the master is
possible.

Ĉ Device

Operational

DeviceNet in the status Data exchange" and connected
to a master

Ĉ Device in

Standby

No connection with the DeviceNet master, device is ready
for operation

Ĉ Minor Fault

Recoverable fault has occurred (e.g. timeout)

Ĉ Unrecoverable

Fault

Serious fault detected (e.g. duplicated MAC ID); a reset
is needed to make the device ready for operation again.

Baudrate

Preset baud rate of the SFC−LACI

MAC ID

Address of the SFC−LACI

I/O Datalength

Set I/O data length.
Ĉ 8 bytes: only FHPP standard (the SFC−LACI is

controlled as per the Festo Handling and Positioning
Profile).

Ĉ 16 bytes: FHPP standard and FPC (additional use of

the FPC for parameterising the SFC−LACI)

[SW information]

SFC−LACI firmware version

Tab. 4/3:

[Diagnostic] menu