5. Commissioning

5−26

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Device Control

When the SFC−LACI is switched on, the controller interface is
activated as standard [HMI = off ].

Caution
Unexpected movements of the drive due to incorrect
parameterising

·

Make sure that there is no active ENABLE signal when
switching on the SFC−LACI on the controller interface.

·

Parameterise the entire system completely before
activating the controller with ENABLE (controller
interface), Enable" (FCT), or [HMI = on] (control panel).

In order that the Festo Configuration Tool can control the
connected SFC−LACI, the control interface of the SFC−LACI
must be deactivated and control must be enabled in the FCT.
The actual status of the control bit ENABLE then has no effect.

·

To do this, go to the Project Output" window, select the
Operate" tab and ,under Device Control", activate the
FCT" checkbox.
The controller interface of the SFC−LACI will then be
deactivated and Control Enable will be set for the FCT.