1. System summary

1−11

Festo GDCP−SFC−LACI−DN−EN en 0812NH

1.1.5

Measuring reference system

Homing

Homing determines the position of the homing reference
point REF. When homing is concluded, the axis stands at the
axis zero point AZ.

The homing method

The homing method defines how the homing point REF is
determined.

Reference point REF

binds the measuring reference system to a proximity sensor
or a fixed stop, depending on the homing method.

Axis zero point AZ

is shifted by a defined distance to the reference point REF
(offset of the axis zero point).
The software end positions and the project zero point are
defined in relation to the axis zero point.

Project zero point PZ

is a point within the effective stroke which the user can freely
select and to which both the actual position and the target
positions in the position record table refer.
The project zero point is shifted by a defined distance to the
axis zero point AZ (offset of the project zero point). The offset
of the project zero point cannot be adjusted via the control
panel.

Software end positions

limit the permitted positioning range (effective stroke). If the
target position of a positioning command lies outside the
software end positions, the positioning command will not be
processed and an error will be registered.

Effective stroke

The distance between the two software end positions.
The maximum stroke which the axis can perform with the
parameters currently set.

Offset reference point

The distance of the reference point REF from the retracted
end position (tolerance +/− 1 mm). For reasons of technical
control, this has to be measured and parameterised.
See figures in Tab. 1/2 and Tab. 1/3.

Advertising