Start/stop record – Festo Контроллеры двигателя SFC-LAC User Manual

Page 167

Advertising
background image

5. Commissioning

5−63

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Start/stop record

Setpoint record
number
Output data

Stop
CCON.B1 (STOP)

Acknowledge start
SPOS.B1 (ACK)

Motion Complete
SPOS.B2 (MC)

Actual record
number
Input data

N − 1

N

N + 1

N − 1

N

1

0

1

0

1

0

1

0

1

0

1

2

3

4

6

1

0

1

0

Axis is moving
SPOS.B4 (MOV)

Start
CPOS.B1 (START)

N + 1

5

1

Requirement:
Acknowledge start" = 0

2

Rising edge at START causes the new
record number N to be accepted and
Acknowledge start" to be set

3

As soon as Acknowledge start" is
recognized by the PLC, START may be
set to 0 again

4

The controller reacts with a falling
edge at Acknowledge start"

5

As soon as Acknowledge start" is
recognized by the PLC, the next record
number may be started

6

A currently running positioning task
can be stopped with STOP

Fig. 5/3:

Sequence diagram for start/stop record