Festo Контроллеры двигателя SFC-LAC User Manual
Page 276
![background image](/manuals/464472/276/background.png)
B. Parametrizing via field bus
B−56
Festo GDCP−SFC−LACI−DN−EN en 0812NH
Digital Inputs
PNU
303
ć
uint32
r
Description
Mapping the digital inputs
Bit 0:
Negative limit switch
Bit 1:
Positive limit switch
Bit 2
Reference switch
Bit 3 ... 15:
reserved (= 0)
Bit 16 ... 20:
Current record number (compare control byte 3)
Bit 21:
STOP (CCON.B1)
Bit 22:
ENABLE (CCON.B0)
Bit 23:
START (CPOS.B1)
Bit 24:
Sample input
Bit 25 ... 31:
reserved (= 0)
CI
60FDh
00h
uint32
r
DeviceNet
C: 103
Aā: 10
I: 1
uint32
r
Digital Outputs
PNU
304
1 ... 2
uint32
r
Description
Mapping the digital outputs
Local Digital
Outputs
304
1
Outputs
Bit 0:
Status of brake
Bit 1 ... 15:
(reserved)
Bit 16 :
MC
Bit 17:
READY
Bit 18:
EA_ACK
Bit 19:
ERROR
Bit 20 ... 24:
(reserved)
Bit 25:
Status Out1
Bit 26:
Status Out2
ć 304
2
(reserved)
CI
60FEh
01h ... 02h
uint32
r
DeviceNet
C: 103
Aā: 20 ... 21
I: 1
uint32
r