Festo Контроллеры двигателя SFC-LAC User Manual
Page 270
Advertising
![background image](/manuals/464472/270/background.png)
B. Parametrizing via field bus
B−50
Festo GDCP−SFC−LACI−DN−EN en 0812NH
Diagnostic Memory Parameter
PNU
204
1 ... 4
uint8
r(w)
Description
Configuration of the diagnostic memory
Fault Type 204
1
rw
1 (0x01): Record incoming and outgoing
*)
faults (default)
2 (0x02): Log only incoming faults
*)
Outgoing fault = Acknowledge the fault
Resolution 204
2
rw
1 (0x01): Resolution time stamp 10 ms (default)
2 (0x02): Resolution time stamp 1 ms
Clear Memory 204
3
rw
Clear diagnostic memory by writing value = 1
Reading is always answered with value = 1
Number of Entries 204
4
r
Number of entries in the diagnostic memory
CI
20CCh
01h ... 04h
uint8
rw/r
DeviceNet
C: 102
Aā: 1 ... 4
I: 1
uint8
rw/r