4. Control panel (only type SFC−LACI−...−H2)

4−6

Festo GDCP−SFC−LACI−DN−EN en 0812NH

4.2

The menu system

Status display and main menu

When the logic voltage is switched on, the SFC−LACI carries
out an internal check.

During the first commissioning or when the EEPROM is
deleted, the error message DeviceNet INIT PARAMETER
ERROR" will appear, as the field bus parameters are not
parameterised (see section 5.2.1).

When the device is switched on again (i.e. when the field bus
parameters have already been completely parameterised
once), the display will show briefly the Festo logo then change
to the status display.

The

status display shows the following information:

ć

The type designation of the SFC−LACI

ć

The type of connected drive

ć

The position of the drive x

a

= ...

(still without significance when unit is switched on)

ć

The current setting of the device control
(HMI = Human Machine Interface)

The

main menu is accessed from the status display using the

<Menu> key. The currently active key function is displayed in
the lower lines of the LCD display.

DeviceNet INIT
PARAMETER ERROR

Diagnostic <menu>

Config <Enter>

SFC–LACI...
D...
Xa = 0.00 mm

HMI:off
<Menu>

}

Diagnostic
Positioning
Settings
V

ESC <Menu>

<––>

OK <Enter>

}

HMI control
LCD adjustment

v

ESC <Menu>

<––>

OK <Enter>