Network Manager Configuration

Set STDMA Flag

It is important for the operator to set the STDMA flag on the network burst

controller(s). The VMS sets the flags for the other network devices automati-

cally.

1.

Right-click on the BC demodulator and select Properties from the drop-

down menu (figure 3-49).

Figure 3-49 Hub BC Demodulator Properties menu command

2. The dialog appearance with the correct setting is shown in the figures below.

For a CDM-570/570L Burst Controller, select the Modem dialog, then

select the STDMA radio button, figure 3-50.

For an SLM-5650A Burst Controller, select the Burst Controller check

box, figure 3-51.
Note for SLM-5650A Hub BC redundacy configurations: Do NOT select

the Burst Controller check box on redundant units. This flag is

unnecessary and may cause network communication problems. Should a

failover occur, the redundant unit will be automatically configured

exactly as the online unit, and this flag will be set correctly at that time.