N:M Hub Modem Redundancy

MN/22156, rev 12

C-32

VMS User Guide

mends using VLOAD to maintain backups of all network units. These backup

files can be used for this purpose.
Install the replacement unit in the desired rack location and make all connec-

tions. The unit should be powered on, but insure the switch port is powered off.

Restoring Acting Primary Unit Spare Configuration

Since the backup unit assumed the identity of the failed primary unit during

restoration, it will appear in the Subnet Manager as the original unit. Right-click

on the unit and open the Properties page. Go to the Configuration tab and select

the appropriate spare configuration imported in the preceding step. Be sure to

select the proper configuration to avoid IP address conflicts.
Select Restore to load the configuration.

Figure C-33 Restoring Configuration

At this point, the network segment controlled by this primary unit will go down.

Power up the new primary unit using the drop down menu on the strip, or in the

sub-group. If the configuration is correct, the network segment will automati-

cally come back up after the unit reboots.

Cleaning up

Once the network has been restored, it will be necessary to create new configu-

ration backups from the drop-down menus and to reset the system roles. Insure

the status is OK. (It may be necessary to reset heartbeat flags)