Proxy caching support, Proxy caching support . . . . . . . . . . . . f-6 – Comtech EF Data VMS v3.12.x Vipersat User Manual

Page 504

Advertising
background image

Proxy Caching Support

MN/22156, rev 12

F-6

VMS User Guide

Proxy Caching Support

When operating as a proxy on behalf of Comtech network equipment, the VMS

will fulfill the requests for a subset of the MIB using data collected via proprie-

tary protocols. When a request is made for one of these MIB variables, the VMS

will report the last known value without forwarding the request to the end node.

This data is collected at a frequency of at least once per minute.
To use the proxy/cache support, send SNMP queries for the modem to the

VMS, and use a specially formatted community string to identify what device is

being queried. The community string format is “community@ip-address”. For

example, to target a device with the IP address of 172.16.128.1, using a read

community of public, the community string sent to VMS would be

[email protected]”.