Comtech EF Data VMS v3.12.x Vipersat User Manual

Page 281

Advertising
background image

Chapter

4 -

Configuring Network Modems

4-63

MN/22156, rev 12

Devices

ACM Link Adaptation can be enabled for the VersaFEC return path between

the CDM-840 modulator and the CDD-880 demodulator (see section “Network

| WAN | ACM” on page 4-37).
Click in the ACM Enable check box to activate the feature.
Select the desired Target Es/N0 Margin (0.0–4.5 dB) from the drop-down

menu.

Because the switch points for the ACM feature can determine whether or not

ModCod oscillations occur, this is a very important parameter. Increasing

these switch points is recommended, for example, in an environment that

will experience fading. Adding sufficient margin will help to maintain

demod lock and adequate link quality.

Set the Maximum ModCod, based on the site link budget calculations.

Important: After setting the Maximum ModCod parameter for the CDM-

840, this same setting must be entered for the Remote Site for this unit:

Under the ViperView Network Manager, right-click on the Remote Site

in the tree view and select Properties.

Select the InBand Return Path ModCods menu item, as shown in

figure 4-40, and set the Default Parameters to match the ACM

Maximum ModCod for the unit.