Rx terminal mix, Acquisition range, Eb/n0 alarm point – Comtech EF Data VMS v3.12.x Vipersat User Manual

Page 286: Devices | lnb, Devices | lnb -68

Advertising
background image

Devices

MN/22156, rev 12

4-68

VMS User Guide

Enabling this parameter will recover the randomized data stream transmitted

from a Remote that has the Scrambler feature enabled. This function creates

energy dispersal of the carrier signal to realize coding gain for the receiver,

such as when there is no traffic being passed and power is concentrated in a

narrow frequency band.

Rx Terminal Mix

The Terminal Mix polarity for the received signal can be set per site

requirements:

[+] indicates a high side, inverting mix (default)

[–] indicates a low side, non-inverting mix

Acquisition Range

The frequency Acquisition Range (to acquire signal lock) for the Hub demod

can be specified with this setting. The maximum range depends on the

symbol rate. Default is 10 kHz.

Eb/N0 Alarm Point

The receive E

b

/N

0

level that will generate an alarm condition for this Hub

demod can be set with this parameter.
Valid range is 0.1–16.0 dB. Default is 0 (disabled).

Devices | LNB

This menu item appears for CDM-840 units only.
Click on the LNB menu item to configure the Remote Downconverter settings

(figure 4-43).