Status and Control

MN/22156, rev 12

5-2

VMS User Guide

Status and Control

ROSS Status View

The status information for any Vipersat network ROSS can be displayed in the

right panel from the Status View interface within ViperView (figure 5-2) by

clicking on the ROSS unit appearance in the left panel. To display the current

status, select the Refresh command from the Status View menu.

Figure 5-1 ROSS Status View, ViperView

The following status information is provided:

• Service Area – Identifies the existing service area for this ROSS.
• Transmit Status – Indicates whether the transmit is Enabled or Disabled.

When the status is enabled, the ROSS is in a valid service area and the

communication poll status of the associated modem and the ACU are

successful. When the status is disabled, the modulator transmit carrier is

muted, regardless of any other controls.

• Last position – Identifies the latitude and longitude coordinates, in

decimal degrees, that were retrieved from the most recent ACU poll. If the

reported position is within a coordinated area, the coordinated area ID will

be displayed adjacent to the coordinates. ROSS polls the ACU for position

on a five second interval. This value is updated by the Refresh command.