Redundancy, General, Appendix c – Comtech EF Data VMS v3.12.x Vipersat User Manual

Page 411: Appendix c, "redundancy, Edundancy

Advertising
background image

Appendix

C -

Redundancy

C-1

A

P P E N D I X

R

EDUNDANCY

General

This appendix describes the optional redundancy services that protect critical

Vipersat network equipment. The two main services offered are VMS Redun-

dancy and Hub Modem Redundancy.
VMS Redundancy provides for N:1 redundant VMS server(s) (standby) co-

located at the Hub alongside the active VMS server. This configuration provides

for the automatic switch-over to a standby server in the event of a failure of the

active server.
Hub Modem Redundancy provides for the operation of N:M multiple primary

and multiple secondary modems installed at the Hub. If a protected device fails,

its output is automatically removed from the satellite network. A replacement

device, loaded with the failed device’s configuration, is booted into service and

its output is switched into the satellite network, replacing that of the failed

device.

Advertising