Hardware Configuration

MN/22156, rev 12

3-6

VMS User Guide

Once the modem/routers have the minumum required configuration and an

installer successfully points the antenna at the satellite and establishes a receive

link, the operator at the Hub site can push frequencies, bit rates, and FEC code

rates to the units at remote sites using the VMS. The frequencies can be

anywhere in the customer’s frequency pool, allowing a thin-route SCPC

connection to be established with the satellite network’s modems.
For example, once communication is established, the Hub operator can set up

the unit for STDMA using the instructions found in each modem manual. After

a reset, the unit will come back online operating in STDMA mode with the

desired configuration.
Once communication is established between VMS and all network devices, the

network is ready to be configured.