570l, Cdm-570/570l – Comtech EF Data VMS v3.12.x Vipersat User Manual

Page 447

Advertising
background image

Appendix

C -

Redundancy

C-37

MN/22156, rev 12

N:M Hub Modem Redundancy

use this IP address, make certain that the IP address is on the Hub subnet and

is not being used by any other active or backup unit.

Figure C-36 Ethernet Interface page, CDM-570/570L

6. On the

Vipersat Configuration

page shown in figure C-37, set the Unit

Role to Hub Expansion.

7. This completes setting the unit to the Parked Configuration mode if it is a

CDM-564L. It is possible the unit was being used to supply voltage to a

LNB, which is described below.

Figure C-37 Vipersat Configuration page, CDM-570/570L

8. On the

Satellite Modem Configuration > Configuration > Tx Config-

uration

page shown in figure C-38, disable the unit’s transmit capability by

changing the Tx Carrier to [Off].