Figure 4-39 versafec modulator dialog, cdm-840 – Comtech EF Data VMS v3.12.x Vipersat User Manual

Page 277

Advertising
background image

Chapter

4 -

Configuring Network Modems

4-59

MN/22156, rev 12

Devices

For the CDM-840 Remote unit, the transmitter configuration settings are

presented for the VersaFEC return path (figure 4-39).

Figure 4-39 VersaFEC Modulator dialog, CDM-840

In order to gain entry in the network and register with the VMS, the CDM-840

Remote modulator requires minimal configuration by the operator due to the

fact that many of the transmit parameters are automatically set according to the

TAP message that is received from the HCC. Only the following parameters

have to be set manually, as determined by the site link budget:

Tx Scrambler, Roll Off, and Spectrum Invert
Power Level
Carrier State – Must be set to On for modem to transmit

Once the Remote is successfully registered, the modulator parameter settings

are managed by the VMS, except for:

FEC Type – This is fixed at VersaFEC
Tx Scrambler, Roll Off, and Spectrum Invert

Advertising