Calls, Traps, and Returns

7-12

-

RETI

cond returns from traps or calls like the RETScond, with the addition

that RETI

cond also sets the GIE bit of the status register, which enables

all interrupts whose enabling bit is set to 1. The conditions for RETI

cond

are the same as for the CALL

cond instruction.

Functionally, calls and traps accomplish the same task — a subfunction is
called and executed, and control is then returned to the calling function. Traps
offer two advantages over calls:

-

Interrupts are automatically disabled when a trap is executed. This allows
critical code to execute without risk of being interrupted. Traps are generally
terminated with a RETI

cond instruction to reenable interrupts.

-

You can use traps to indirectly call functions. This is particularly benefi-
cial when a kernel of code contains the basic subfunctions to be used by
applications. In this case, you can modify the functions in the kernel and
relocate them without recompiling each application.

Figure 7–1. CALL Response Timing

Read CALL

H3

H1

ADDR

Data

Fetch CALL

Fetch first

subroutine

instruction

Vector address

First instruction

address

Execute CALL

(store PC

on stack)

Decode CALL

PC

Inst 1

Advertising