Restore Clock to Regular Speed

MAXSPEED

13-145

Assembly Language Instructions

Syntax

MAXSPEED

(supported by ’C31, ’C32, ’C31 silicon revision 5.0
or greater, ’C30 silicon revision 7.0 or greater)

Operation

H1/16

H1

Operands

None

Opcode

31

23

16

8 7

0

15

0 0 0

1 0

0

0

1

0

0

0 0

0

0

0 0

0

0

0 0

0

0

0 0

0

0 0

0

0

0 0

0

Description

Exits LOPOWER power-down mode (invoked by LOPOWER instruction with
opcode 10800001h). The ’LC31 or ’C32 resumes full-speed operation during
the read phase of the MAXSPEED instruction.

Cycles

1

Status Bits

LUF

Unaffected

LV

Unaffected

UF

Unaffected

N

Unaffected

Z

Unaffected

V

Unaffected

C

Unaffected

OVM

Operation is not affected by OVM bit value.

Example

MAXSPEED

; The processor resumes full-speed operation.