B. Reference – Festo DeviceNet and FHPP
B-51
Festo P.BE-MTR-DCI-DN-EN en 1209a
B.2.19 Axis parameter, electric drive 1 – Standstill monitoring
Position Target Value
FHPP
1040
–
Var
int32
ro
Description
Target position of the last positioning task, in increments.
Value range: -2
31
... +(2
31
-1)
CI
6062h
00h
Var
int32
ro
DeviceNet
6Bh
01h
44h
int32
ro
Position Actual Value
FHPP
1041
–
Var
int32
ro
Description
Current position of the drive in increments.
Value range: -2
31
... +(2
31
-1)
CI
6064h
00h
Var
int32
ro
DeviceNet
6Bh
01h
45h
int32
ro
Standstill Position Window
FHPP
1042
–
Var
uint32
rw
Description
Standstill position window in increments: Distance that the drive can move
after “Motion Complete” before standstill monitoring reports. Value range:
0...+(2
32
-1). Default: 750 (0x02EE)
CI
2040h
00h
Var
uint32
rw
DeviceNet
6Bh
01h
46h
uint32
rw
Standstill Timeout
FHPP
1043
–
Var
uint16
rw
Description
Standstill monitoring time in [ms] : time for which the drive must be outside the
standstill position window before standstill monitoring responds.
Value range: 0...65535 (0xFFFF). Default: 200 (0x00C8)
CI
2041h
00h
Var
uint16
rw
DeviceNet
6Bh
01h
47h
uint16
rw