Position Control Parameter Set

FHPP

1024

18...23, 32

Array

uint16

rw

Description

Control parameters.
Modification is only permitted for service purposes.
If necessary consult Festo.

Gain Position 1024

18 (CI: 12h)

rw

Gain for position controller.
Value range:
MTR-DCI-32:1...100;

MTR-DCI-42/52/62: 1...200

Default:
MTR-DCI-32:20;

MTR-DCI-42:15;

MTR-DCI-52:10;

MTR-DCI-62:8

Gain Velocity 1024

19 (CI: 13h)

rw

Gain for speed controller.
Value range: MTR-DCI-32: 1...3000; MTR-DCI-42/52/62: 1...700
Default: MTR-DCI-32: 2800; MTR-DCI-42/52: 600; MTR-DCI-62: 500

I-Fraction Velocity 1024

20 (CI: 14h)

rw

Integral term for speed controller.
Value range: 1...600
Default: MTR-DCI-32: 80; MTR-DCI-42/52/62: 340

Gain Current 1024

21 (CI: 15h)

rw

Gain for current controller
Value range: MTR-DCI-32: 1...1000; MTR-DCI-42/52/62: 1...800
Default: MTR-DCI-32: 110; MTR-DCI-42/52/62: 150

I Fraction

1024

22 (CI:16h)

rw

Integral term for current regulator
Value range: MTR-DCI-32/42/52: 0...1000
Default: MTR-DCI-32: 90; MTR-DCI-42: 420; MTR-DCI-52: 350

Gain Velocity

Trajectory

1024

23 (CI: 17h)

rw

Gain for speed controller – trajectory generator.
Value range: 1...2. Default: 1

Save Position 1024

32 (CI: 20h)

rw

Saves current position in the EEPROM when power is switched off.
Fixed = 240 (0x00F0): current position is not saved at Power-Off.

CI

60FBh

12h...17h, 20h

Array

uint16

rw

DeviceNet

6Bh

01h

22h...28h

uint16

rw