1 [positioning] [move position set – Festo Электромотор MTR-DCI User Manual
Page 86
Move position set
Position no.:
[1...31] = _?
ESC <Menu>
EDIT <-->
OK <Enter>
Move position set
Attention! Motor moves
ESC <Menu>
START <Enter>
4. The control panel (type MTR-DCI-...-H2 only)
4-12
Festo P.BE-MTR-DCI-DN-EN en 1209a
For selecting a positioning run or a homing run:
1. From the main menu, select the [Positioning] menu.
2. Select the menu command:
–
[Move position set] to test a particular positioning set
in the positioning set table (see chapter 4.4.1).
–
[Demo posit tab] to run all position set records in the
position set table one after the other.
–
[Homing] Homing run to determine the dimensional
reference system (see chapter 4.4.3).
4.4.1
[Positioning] [Move position set]
Note
Do not start a position set record until the reference
system has been defined by homing.
To test a particular position set record in the position set
table:
1. Select the position set number.
<- ->
Select the desired number using the arrow buttons.
OK
Confirm the selection using the <Enter> button.
ESC
Pressing the <Menu> button cancels the action and
returns you to the higher menu level.
2. Start positioning with START <Enter>.
During the positioning run, the following information is dis-
played:
–
The active positioning set, e.g. Pos 2
} Positioning
Move position set
Demo posit tab
Homing