Move position set
Position no.:
[1...31] = _?

ESC <Menu>

EDIT <-->

OK <Enter>

Move position set
Attention! Motor moves

ESC <Menu>
START <Enter>

4. The control panel (type MTR-DCI-...-H2 only)

4-12

Festo P.BE-MTR-DCI-DN-EN en 1209a

For selecting a positioning run or a homing run:

1. From the main menu, select the [Positioning] menu.

2. Select the menu command:

[Move position set] to test a particular positioning set
in the positioning set table (see chapter 4.4.1).

[Demo posit tab] to run all position set records in the
position set table one after the other.

[Homing] Homing run to determine the dimensional
reference system (see chapter 4.4.3).

4.4.1

[Positioning] [Move position set]

Note
Do not start a position set record until the reference
system has been defined by homing.

To test a particular position set record in the position set
table:

1. Select the position set number.

<- ->

Select the desired number using the arrow buttons.

OK

Confirm the selection using the <Enter> button.

ESC

Pressing the <Menu> button cancels the action and
returns you to the higher menu level.

2. Start positioning with START <Enter>.

During the positioning run, the following information is dis-
played:

The active positioning set, e.g. Pos 2

} Positioning

Move position set