6 [settings] [bus parameter – Festo Электромотор MTR-DCI User Manual
Page 97

4. The control panel (type MTR-DCI-...-H2 only)
4-23
Festo P.BE-MTR-DCI-DN-EN en 1209a
5. Confirm the digit with OK <Enter>.
6. Set the digit for the next input position “?”.
7. After entering the third digit, save your setting with SAVE
<Enter>.
4.5.6
[Settings] [BUS parameter]
Setting Fieldbus parameters.
[BUS parameter] Param.
Description
[MAC ID]
0 ... 63
(0 ...3fh)
Fieldbus address of the MTR-DCI.
Representation:
“0 dec, 0 hex”...“63 dec, 3f hex”
[Bit rate]
500 kbit/s,
250 kbit/s,
125 kbit/s
Fieldbus bit rate corresponding to the settings on the master.
[I/O DATA]
8 bytes
16 bytes
I/O data length setting
–
8 bytes: only for the FHPP standard (control of the MTR-DCI
is done as per the Festo Handling and Positioning Profile)
–
16 bytes: FHPP standard and FPC (additional use of the
Festo Parameter Channel for parameterising the MTR-DCI)
Tab. 4/10: [Settings] [BUS Parameter] menu
<- ->
Select the parameter setting using the arrow
buttons.
OK
Confirm the selection using the <Enter> button.
ESC
Pressing the <Menu> button cancels the action and
returns you to the higher menu level.
The settings made in the [BUS Parameter] menu are saved
directly and permanently (including in the event of a power
failure) to the EEPROM when you confirm them with
OK<Enter>.