B. Reference – Festo DeviceNet and FHPP

B-19

Festo P.BE-MTR-DCI-DN-EN en 1209a

Device Control

FHPP

125

Var

uint8

rw

Description

Activates device control of the controller via the controller interface.
Corresponds to “HMI control” on the control panel and “FCT/HMI” in the FCT.
0 (0x00): Control via control interface OFF,

via HMI (control panel) and FCT ON

1 (0x01): Control via controller interface OFF (default)

CI

207Dh

00h

Var

uint8

rw

DeviceNet

64h

01h

0Eh

uint8

rw

HMI Control

FHPP

126

1...4

Var

uint8

ro

Description

Settings for the HMI control panel (for MTR-DCI-...-H2 only)
Only affects the values in the display: all parameters are stored in increments.

LCD Current

(LCD voltage)

126

1

0

ro

Value range: 1...5 (0x01 ... 0x05). Default: 5

LCD Contrast 126

2

1

ro

Value range: 0...63 (0x00 ... 0x3F). Default: 0

Measuring unit 126

3

2

CI: rw

Measuring unit system for the control panel. See object 20D0h.
1 (0x01): metric units of measurement (mm, mm/s, mm/s

2

)

4 (0x04): angular degrees
8 (0x08): revolutions

Scaling Factor 126

4

3

CI: rw

Number of decimal places. Fix = 2. See object 20D0h

CI

20FFh

01h...04h

Array

uint8

rw

DeviceNet

64h

01h

0Fh...12h

uint8

rw