3 fault messages, 1 overview, 3 fault messages 6.3.1 overview – Festo Электромотор MTR-DCI User Manual
Page 197

6. Diagnosis and error display
6-7
Festo P.BE-MTR-DCI-DN-EN en 1209a
6.3
Fault messages
6.3.1
Overview
Cate-
gory
Name, display
Description
Device
Error
1)
Fault
number
Fault
LED
Status
bytes
2)
Fault
POSITION ERROR
Following error
0x0001
31
ON
FAULT, DEV
Fault
MOTOR STOP
Motor stop
0x0002
106
ON
FAULT
Fault
HOMING-ERROR
Reference run
fault
0x0004
32
ON
FAULT
Fault
OVERHEATING
Overtemperature
(ActTemp > 80°C)
0x0008
101
ON
FAULT
Fault
LOAD-POWER-
DOWN
Load voltage
monitoring
0x0010
70
ON
FAULT
Fault
I2t-ERROR
Current moni-
toring (i
2
t)
0x0020
100
ON
FAULT
Fault
HARDWARE-ERROR
Device fault
0x0040
52
ON
FAULT
Fault
TARGET POSITION
OUT OF LIMIT!
Nominal position
not reachable
0x0080
2
ON
FAULT
Warning
ILLEGAL RECORD
Invalid record
number
0x0100
3
FLASH-
ING
WARN
Fault
PLEASE ENFORCE
HOMING RUN!
Homing required
0x0200
1
ON
FAULT
Warning
STANDSTILL-
WARNING
Standstill moni-
toring
0x4000
36
FLASH-
ING
WARN,
STILL
Fault
INIT NO PARA-
METER ERROR
Fault:
Bus parameters
not set.
0x8000
51
ON
FAULT
1)
See PNU 205 / CI 2FF1/00
2)
For FHPP status bytes, see section 5.5.2