3 fault messages, 1 overview, 3 fault messages 6.3.1 overview – Festo Электромотор MTR-DCI User Manual

Page 197

Advertising
background image

6. Diagnosis and error display

6-7

Festo P.BE-MTR-DCI-DN-EN en 1209a

6.3

Fault messages

6.3.1

Overview

Cate-
gory

Name, display

Description

Device
Error

1)

Fault
number

Fault
LED

Status
bytes

2)

Fault

POSITION ERROR

Following error

0x0001

31

ON

FAULT, DEV

Fault

MOTOR STOP

Motor stop

0x0002

106

ON

FAULT

Fault

HOMING-ERROR

Reference run
fault

0x0004

32

ON

FAULT

Fault

OVERHEATING

Overtemperature
(ActTemp > 80°C)

0x0008

101

ON

FAULT

Fault

LOAD-POWER-
DOWN

Load voltage
monitoring

0x0010

70

ON

FAULT

Fault

I2t-ERROR

Current moni-
toring (i

2

t)

0x0020

100

ON

FAULT

Fault

HARDWARE-ERROR

Device fault

0x0040

52

ON

FAULT

Fault

TARGET POSITION
OUT OF LIMIT!

Nominal position
not reachable

0x0080

2

ON

FAULT

Warning

ILLEGAL RECORD

Invalid record
number

0x0100

3

FLASH-
ING

WARN

Fault

PLEASE ENFORCE
HOMING RUN!

Homing required

0x0200

1

ON

FAULT

Warning

STANDSTILL-
WARNING

Standstill moni-
toring

0x4000

36

FLASH-
ING

WARN,
STILL

Fault

INIT NO PARA-
METER ERROR

Fault:
Bus parameters
not set.

0x8000

51

ON

FAULT

1)

See PNU 205 / CI 2FF1/00

2)

For FHPP status bytes, see section 5.5.2

Advertising