3. Installation
3-5
Festo P.BE-MTR-DCI-DN-EN en 1209a
The plug connectors of the following Festo cables have been
designed so that, when inserted and screwed tight, or if fitted
with protective covers, the connections on the MTR-DCI will
comply with protection class IP54.
Caution
Long lines reduce immunity to interference (EMC).
•
Do not exceed the specified maximum cable lengths.
Connection
Cable
Designation
Length [m]
Serial interface
Programming cable
KDI-MC-M8-SUB-9-2,5
2.5 (max. 2.5)
Homing Switch
Connecting cable
KM8-M8-GSGD-...
0.5 / 1 / 2 / 5
Fieldbus interface
Field bus plug for M12
adapter
FBA-CO-SUB-9-M12
–
Voltage supply
Power supply cable
KPWR-MC-1-SUB-9HC-...
2.5 / 5 / 10
(max. 10)
Tab. 3/2: Overview of cables (accessories)
To maintain the IP protection class:
•
Seal unused M8 connections with ISK-M8 protective caps
(accessories).
•
Hand-tighten the union nuts/locking screws of the plugs:
Observe the permitted tightening torques specified in the
documentation for the cables and connectors used.