5. Commissioning

5-38

Festo P.BE-MTR-DCI-DN-EN en 1209a

CDIR

Control byte CDIR is a special control byte for operating mode
“Direct task”.

Control byte 3 (CDIR) – Direct task only

Bit

EN

Description

B0
ABS

Absolute/
Relative

= 0: Nominal value is absolute
= 1: Nominal value is relative to last nominal value

B1
COM1

Control Mode

= 00: Positioning operation (see also 5.5.7 point 6)
= 01: Force operation (see also 5.5.7 point 7)
= 10: Reserved
= 11: Reserved

B2
COM2

B3
CONT

Reserved
: = 0

B4
VLIM

Reserved
: = 0

B5
XLIM

Stroke (

X-)

limit not active

Force control:
= 0: Stroke monitoring active
= 1: Stroke monitoring not active

B6
FAST

Reserved
: = 0

B7
FUNC

Reserved
: = 0