3 power supply, 1 power supply requirements – Festo Электромотор MTR-DCI User Manual

Page 63

Advertising
background image

3. Installation

3-7

Festo P.BE-MTR-DCI-DN-EN en 1209a

3.3

Power supply

3.3.1

Power supply requirements

Warning

•

In order to provide the electric power supply, use only
PELV

circuits as per IEC/DIN EN 60204-1 (Protective

Extra-Low Voltage, PELV).
Take into account also the general requirements for
PELV circuits as per IEC/DIN EN 60204-1.

•

Use only

power sources providing reliable electrical

isolation of the operating voltage as per IEC/DIN
EN 60204-1.

By the use of PELV power units, protection against electric
shock (protection against direct and indirect contact) is guar-
anteed in accordance with IEC/DIN EN 60204-1 (electrical
equipment of machines, general requirements).

Caution
Device damage from overvoltage

The voltage inputs of the motor unit have no internal
protection against overvoltage.

•

Make sure that the permitted voltage tolerance is not
exceeded. The tolerance must also be observed directly
at the operating voltage connections on the MTR-DCI
(see appendix A.1).

•

Install external fuses (see Tab. 3/4).

Advertising