3. Installation

3-7

Festo P.BE-MTR-DCI-DN-EN en 1209a

3.3

Power supply

3.3.1

Power supply requirements

Warning

In order to provide the electric power supply, use only
PELV

circuits as per IEC/DIN EN 60204-1 (Protective

Extra-Low Voltage, PELV).
Take into account also the general requirements for
PELV circuits as per IEC/DIN EN 60204-1.

Use only

power sources providing reliable electrical

isolation of the operating voltage as per IEC/DIN
EN 60204-1.

By the use of PELV power units, protection against electric
shock (protection against direct and indirect contact) is guar-
anteed in accordance with IEC/DIN EN 60204-1 (electrical
equipment of machines, general requirements).

Caution
Device damage from overvoltage

The voltage inputs of the motor unit have no internal
protection against overvoltage.

Make sure that the permitted voltage tolerance is not
exceeded. The tolerance must also be observed directly
at the operating voltage connections on the MTR-DCI
(see appendix A.1).

Install external fuses (see Tab. 3/4).

Advertising