5. Commissioning

5-32

Festo P.BE-MTR-DCI-DN-EN en 1209a

5.5.2

Structure of the cyclic I/O data (FHPP standard)

The FHPP protocol stipulates 8 bytes of input data and
8 bytes of output data.

Further 8 byte I/O according to FHPP-FPC
In the cyclic data a further 8 bytes of input data and 8 bytes
of output data are permissible for transmitting parameters
according to the FPC protocol (Festo Parameter Channel).
A description of the I/O data and the parameters is provided
in section 5.7.

Data

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

O data

Bytes 1 and 2 (fix)
are retained in every
operating mode and
transfer control and
status bytes (e.g.
CCon, SCON....) for
enabling the MTR-
DCI and setting the
operating modes

Bytes 3 to 8 depend on the selected operating mode (direct task,
record selection) and transfer further control and/or status bytes
(e.g. CDir, SDir...), as well as nominal and actual values:

Record number or nominal position in the output data

Feedback of actual position and record number in the input data

Additional mode-dependent nominal and actual values.

I data

I/O data: Record selection

Data

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

O data

CCON

CPOS

Record no.

Reserved

Reserved

I data

SCON

SPOS

Record no.

RSB

Actual position

I/O data: Direct Task

Data

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

O data

CCON

CPOS

CDIR

Nominal
value 1
(Velocity)

Nominal value 2
(position, force/torque, ...)

I data

SCON

SPOS

SDIR

Actual
value 1
(position,
force/
torque, ...)

Actual value 2
(Actual position)