B.2.14 project data – direct mode: (force mode) – Festo Электромотор MTR-DCI User Manual

Page 259

Advertising
background image

B. Reference – Festo DeviceNet and FHPP

B-37

Festo P.BE-MTR-DCI-DN-EN en 1209a

B.2.14 Project data – Direct mode: (Force mode)

Force Target Window

FHPP

552

uint16

rw

Description

The amount by which the actual force (or actual torque) may deviate from the
nominal force (nominal torque) and still be regarded as being within the target
window. The width of the window is therefore twice the value transferred, with
the nominal force in the centre of the window. The value is given in 1/1000 of
the nominal torque (6076h / PNU 509). Value range: 0...65535. Default: 100.

CI

60F6h

03h

uint16

rw

DeviceNet

69h

01h

29h

uint32

rw

Damping Time

FHPP

553

uint16

rw

Description

Once the actual force (or actual torque) has been in the target window
this amount of time, the “target reached” bit will be set in the status word
(= motion complete).
Value range: 0...30000 ms. Default: 100 ms.

CI

60F6h

04h

uint16

rw

DeviceNet

69h

01h

35h

uint16

rw

Speed Limit

FHPP

554

uint32

rw

Maximum permitted speed when Force mode is active. In this way the user can
ensure that, if Force mode is activated by mistake (e. g. when workpiece is
missing), the axis will not undergo uncontrolled acceleration and travel at high
speed against a stop. This parameter is evaluated in all controller modes in
which the position controller is

not active when in the “operation enabled”

state. Value range: 1...4.294.967.295 inc/s

CI

60F6h

02h

uint32

rw

DeviceNet

69h

01h

36h

uint32

rw