4 serial interface – Festo Электромотор MTR-DCI User Manual
Page 67

3. Installation
3-11
Festo P.BE-MTR-DCI-DN-EN en 1209a
3.4
Serial interface
Serial interface for parameter assignment, commissioning
and diagnosis
Use the following cable exclusively for connecting a PC to the
MTR-DCI:
– Programming cable KDI-MC-M8-SUB-9-2.5
•
If necessary, remove the protective cap from the serial
interface of the MTR-DCI.
•
Connect the following terminals with the programming
cable:
–
The connection socket on the MTR-DCI.
–
A serial interface COMx on the diagnostic PC.
M8x1 socket
Description
1
2
4
3
1
GND
Ground
2
TXD
RS232 transmitting cable
1)
3
RXD
RS232 receiving cable
1)
4
---
Reserved for service personnel –
do not connect!
1)
The levels conform to the RS232 standard
Data transfer rate: 9600 bit/s
Tab. 3/6: Pin allocation for the serial interface on the
MTR-DCI