Festo Электромотор MTR-DCI User Manual

Page 126

Advertising
background image

5. Commissioning

5-28

Festo P.BE-MTR-DCI-DN-EN en 1209a

5.4.2

Configuration of the DeviceNet master (“I/O configuration”)

Configuration with EDS file “EDS files” are provided for configuration of the master.

These files are installed using the configuration software of
the master. For the detailed procedure refer to the manuals
for the configuration software used.

Sources:

The accompanying CD contains EDS files for the MTR-DCI in
the “DeviceNet” folder. You will also find the latest EDS files
on the Festo website at:

www.festo.com/download/

EDS file:

For the MTR-DCI you will need one of the following EDS files
(in English):

MTR-DCI-

aa-DN-bb1_0.eds

aa:

Sizes 32, 42, 52, 62

bb:

I/O data length (bytes) 08, 16

Graphic file: MTR-DCI.ico.

The configuration of the DeviceNet master must agree with
the parameterisation of the device, otherwise no connection
for cyclic data exchange is possible. If necessary, the I/O data
length can be manually configured in the software for the
master.

Manual configuration

Vendor Code

26 (=1Ah)

Product Type

12 (=0Ch)

Product Code

90

x0 (decimal)

x: size (1st character) 3, 4, 5, 6

You can also find the appropriate device information under
[Device] in the EDS file.