3. Installation

3-4

Festo P.BE-MTR-DCI-DN-EN en 1209a

1

Serial
interface

2

Connection
Reference switch

3

Fieldbus interface
(I/F)

4

Power
supply (Power)

1

2

3

4

Fig. 3/1:

Connections on the MTR-DCI

Connection on the MTR-DCI

Description

1 Serial interface

M8x1, 4-pin

socket

RS232 interface for parameterising, commis-
sioning and diagnosing with FCT

2 Reference switch

M8x1, 3-pin

socket

Sensor input for N.O. (normally open) switch type
in PNP configuration

3 Fieldbus interface

Sub-D, 9-pin

Plug

Interface for connecting the higher-level control
system via Fieldbus (DeviceNet)

4 Power supply

Sub-D, 2-pin

Plug

Connection with two high-current contacts

Tab. 3/1: Description of the connections

If non-assigned plug connectors are touched, there is a
danger that damage may occur to the MTR-DCI or to other
parts of the system as a result of ESD (electrostatic dis-
charge). Place protective caps on unused terminals in order
to prevent such discharges.