5. Commissioning

5-39

Festo P.BE-MTR-DCI-DN-EN en 1209a

5.5.6

Description of the status bytes SCON, SPOS, SDIR (RSB)

Status byte 1 (SCON)

Bit

EN

Description

B0
ENABLED

Drive

enabled

= 0: Drive blocked, controller not active
= 1: Drive (controller) enabled

B1
OPEN

Operation
enabled

= 0: Stop active
= 1: Operation enabled, positioning possible

B2
WARN

Warning

= 0: Warning not present
= 1: Warning present

B3
FAULT

Fault

= 0: No fault
= 1: Fault present / fault response active.

Fault code in fault buffer

B4
24VL

Supply Voltage
is

Applied

= 0: No load voltage
= 1: Load voltage applied

B5
LOCK

Drive Control
by FCT/MMI

= 0: Device control by PLC/Fieldbus
= 1: Device control by FCT/HMI

(PLC control is

locked)

B6
OPM1

Display
operating
mode

= 00: Record selection (Standard)
= 01: Direct task
= 10: Reserved
= 11: Reserved

B7
OPM2