B.2.16 axis parameter, electric drives 1 – homing – Festo Электромотор MTR-DCI User Manual
Page 264
B. Reference – Festo DeviceNet and FHPP
B-42
Festo P.BE-MTR-DCI-DN-EN en 1209a
B.2.16 Axis parameter, electric drives 1 – Homing
Offset Axis Zero Point
FHPP
1010
–
Var
int32
rw
Description
Offset for axis zero point in increments (distance from homing point)
Value range: -2
31
...+(2
31
-1).
CI
607Ch
00h
Var
int32
rw
DeviceNet
6Bh
01h
14h
int32
rw
Homing Method
FHPP
1011
–
Var
int8
rw
Description
Defines the method which the drive uses to carry out homing. The MTR-DCI
supports the following methods:
Values
Function
-17 (0xEF): Search for stop in negative direction
-18 (0xEE): Search for stop in positive direction
23 (17h):
Search for reference switch in positive direction
27 (0x1B):
Search for reference switch in negative direction
Changing the homing method resets the following parameters to the factory
settings:
–
1010
Axis zero point offset
CI
6098h
00h
Var
int8
rw
DeviceNet
6Bh
01h
15h
int8
rw