5. Commissioning

5-63

Festo P.BE-MTR-DCI-DN-EN en 1209a

Start/stop record

Nominal record
number in output
data

Stop CCON.B1
(STOP)

Acknowledge Start
SPOS.B1 (ACK)

Motion Complete
SPOS.B2 (MC)

Actual record
number input data

N – 1

N

N + 1

N – 1

N

1

0

1

0

1

0

1

0

1

0

1

2

3

4

6

1

0

1

0

Axis is moving
SPOS.B4 (MOV)

Start CPOS.B1
(START)

N + 1

5

1

Precondition:
“Acknowledge Start” = 0

2

Rising edge at “Start” results in
application of the new record number
N and setting of “Acknowledge start”

3

As soon as “Acknowledge start” is
detected by the PLC, it can reset
“Start” to 0

4

The controller responds with a falling
edge at “Acknowledge start”

5

As soon as “Acknowledge start” is
detected by the PLC, it can create the
next record number

6

An ongoing positioning operation can
be stopped with “Stop”

Fig. 5/4:

Flow diagram for “start/stop record”