3.5

Input for external reference switch

If you are not using a reference switch:

Seal the connection with the protective cap supplied
(ISK-M8).

When selecting the reference switch:

For the reference switch, use the correct “N.O.”
(normally-open) switch type in PNP configuration.

Use a reference switch with a screw-type lock (external
thread M8x1) at the end of the cable, or use the connect-
ing cable KM8-M8-... with a screw-type lock as an ad-
apter.

Use (e.g.) the following Festo proximity sensors:

magnetic proximity sensor SMT-8M-...

inductive proximity sensor SIEN-...-M8B-...

When selecting the sensor, note that the accuracy of the
switchover point of the sensor determines the accuracy of
the homing (reference) point.

M8x1 socket

Description

1

3

4

1

DC +24 V

DC + 24 V voltage output
(only for reference switch)

4

REF

Reference switch contact

3

GND

Ground

Tab. 3/7: REF connection (reference switch) on the MTR-DCI

The power supply for the reference switch (DC 24 V/Ground)
is provided via pin 1/3.