Festo Электромотор MTR-DCI User Manual
Page 265

B. Reference – Festo DeviceNet and FHPP
B-43
Festo P.BE-MTR-DCI-DN-EN en 1209a
Homing Velocities
FHPP
1012
1, 2
Array
uint32
rw
Description
Speeds during homing in [inc/s].
Search REF 1012
1
uint32
rw
Speed when searching for the homing point (reference point) REF, in [inc/s]
Value range:
MTR-DCI-32:
200...33000
MTR-DCI-42:
200...50000
MTR-DCI-52:
200...50000
MTR-DCI-62:
200...56700
Default:
MTR-DCI-32:
27000
MTR-DCI-42:
22400
MTR-DCI-52/62: 16800
Search AZ 1012
2
uint32
rw
Speed when moving to the axis zero point AZ, in [inc/s]
Value range:
MTR-DCI-32:
200...33000
MTR-DCI-42:
200...50000
MTR-DCI-52:
200...50000
MTR-DCI-62:
200...56700
Default:
MTR-DCI-32:
27000
MTR-DCI-42:
22400
MTR-DCI-52/62: 16800
CI
6099h
01h, 02h
Array
uint32
rw
DeviceNet
6Bh
01h
16h, 17h
uint32
rw
Homing Required
FHPP
1014
–
Var
uint8
rw
Description
Defines whether or not homing must be carried out after switching on in order
to carry out positioning tasks.
With MTR-DCI-DN, homing must ALWAYS be carried out after switching on the
logic voltage supply!
Fixed = 1: Homing must be carried out
CI
23F6h
00h
Var
uint8
rw
DeviceNet
6Bh
01h
19h
uint8
rw