B.2.4 device data – standard parameters – Festo Электромотор MTR-DCI User Manual

Page 239

Advertising
background image

B. Reference – Festo DeviceNet and FHPP

B-17

Festo P.BE-MTR-DCI-DN-EN en 1209a

B.2.4

Device data – Standard parameters

Manufacturer Hardware Version

FHPP

100

Var

uint16

ro

Description

Hardware version, stated in BCD (Binary Coded Decimal): xxyy
(xx = main version, yy = secondary version)

CI

2069h

00h

Var

uint16

ro

DeviceNet

64h

01h

01h

uint16

ro

Manufacturer Firmware Version

FHPP

101

Var

uint16

ro

Description

Firmware version, stated in BCD (Binary Coded Decimal): xxyy
(xx = main version, yy = secondary version)

CI

206Ah

00h

Var

uint16

ro

DeviceNet

64h

01h

02h

uint16

ro

Version FHPP

FHPP

102

Var

uint16

ro

Description

Version number of the FHPP, stated in BCD (Binary Coded Decimal): xxyy
(xx = main version, yy = secondary version)

CI

2066h

00h

Var

uint16

ro

DeviceNet

64h

01h

03h

uint16

ro

Controller Serial Number

FHPP

114

1...12

Array

char

ro

Description

12-character code for unique identification of the controller.
Example: “TD15P0212345”

CI

2072h

00h

Var

V-string

ro

DeviceNet

64h

01h

08h

Short String

ro

Advertising