3. Installation

3-15

Festo P.BE-MTR-DCI-DN-EN en 1209a

3.6

Field bus

3.6.1

Connecting the higher-order controller

Communication with the higher-order controller occurs via
the Fieldbus interface

(I/F)

on the MTR-DCI-...

To connect to the Fieldbus there is a 9-pin Sub-D plug on the
MTR-DCI-...-DN. This connection is used for feed-in and con-
tinuation of the Fieldbus line.

Note
Only the FBA-CO-SUB-9-M12 Fieldbus adapter from Festo
guarantees IP 54 protection.

Note
The shield connection at pin 5 of the Fieldbus interface is
internally capacitively and high resistance connected to
the housing. This prevents compensating currents from
flowing via the shield of the Fieldbus cable (see Fig. 3/3).

1

Capacitive
connection

2

Housing

5

1

9

6

1

2

Fig. 3/3:

Shield connection inside the MTR-DCI

In normal operation, pins 6 and 9 must be supplied with 24 V
(bus voltage and logic voltage supplies). The CAN bus
(pins 2, 3, 7) potential is relative to the bus power supply